Send brother's scan settings on one line and scan from the feeder, both sides, into one PDF (issue 1452)
mesh/merge-gate head d5f9cd465c96 merged into trunk d62c2edc35f3 — pass: builds brother → shanks; no bus step; every machine composes with the change as it…
mesh/repo-check head d5f9cd465c96 merged into trunk d62c2edc35f3 — pass: its merge-check.sh passed, each part in its toolchain: merge-check.sh (go), merge-…
mesh/delivery delivered

The Brother ignores the whole body when it holds a line break, so every setting was ignored and the glass was scanned at its default.
This commit is contained in:
2026-10-21 01:05:55 +02:00
parent 82649bc770
commit d5f9cd465c
17 changed files with 523 additions and 108 deletions
@@ -0,0 +1,6 @@
HTTP/1.1 200 OK
Content-Location: /eSCL/ScanJobs/1b61ed02-ccda-11f1-809a-94ddf83ec78a/doc-33
Accept-Encoding: identity
Content-Type: image/jpeg
Transfer-Encoding: chunked
+1 -9
View File
@@ -1,9 +1 @@
<?xml version="1.0" encoding="UTF-8"?>
<scan:ScanSettings xmlns:scan="http://schemas.hp.com/imaging/escl/2011/05/03" xmlns:pwg="http://www.pwg.org/schemas/2010/12/sm">
<pwg:Version>2.63</pwg:Version>
<pwg:ScanRegions><pwg:ScanRegion><pwg:ContentRegionUnits>escl:ThreeHundredthsOfInches</pwg:ContentRegionUnits><pwg:XOffset>0</pwg:XOffset><pwg:YOffset>0</pwg:YOffset><pwg:Width>2550</pwg:Width><pwg:Height>3507</pwg:Height></pwg:ScanRegion></pwg:ScanRegions>
<pwg:InputSource>Platen</pwg:InputSource>
<scan:ColorMode>RGB24</scan:ColorMode>
<scan:XResolution>300</scan:XResolution><scan:YResolution>300</scan:YResolution>
<pwg:DocumentFormat>image/jpeg</pwg:DocumentFormat>
</scan:ScanSettings>
<?xml version="1.0" encoding="UTF-8"?><scan:ScanSettings xmlns:scan="http://schemas.hp.com/imaging/escl/2011/05/03" xmlns:pwg="http://www.pwg.org/schemas/2010/12/sm"><pwg:Version>2.0</pwg:Version><scan:Intent>Document</scan:Intent><pwg:ScanRegions><pwg:ScanRegion><pwg:ContentRegionUnits>escl:ThreeHundredthsOfInches</pwg:ContentRegionUnits><pwg:XOffset>0</pwg:XOffset><pwg:YOffset>0</pwg:YOffset><pwg:Width>2480</pwg:Width><pwg:Height>3508</pwg:Height></pwg:ScanRegion></pwg:ScanRegions><pwg:InputSource>Feeder</pwg:InputSource><scan:ColorMode>RGB24</scan:ColorMode><pwg:DocumentFormat>image/jpeg</pwg:DocumentFormat><scan:XResolution>200</scan:XResolution><scan:YResolution>200</scan:YResolution><scan:Duplex>true</scan:Duplex></scan:ScanSettings>