Commit Graph
8 Commits
Author SHA1 Message Date
jochen 76b63744e6 Carry the power draw to the bar over the bus, not through a file (hq ADR 0260)
Modules talk over the bus. The power module's bundle puts each fresh reading of its own
sampler in its state draw, keyed by the machine; the bar's block shows that state, which
the bar's bundle watches under the read the mesh grants it. A new catalogue check refuses
a module naming another module's path under /run or /var/lib.
2026-10-08 16:12:37 +02:00
jochen e1b7fcd8c9 Count each processor package once, never read a sleeping card, and give no reading for a reset counter (hq ADR 0255)
Intel shows some packages twice (MSR and MMIO), an AMD card's sensors wake it, and a
counter reset after resume read as thousands of watts. The loop's cadence and the bar
script's staleness are now tested, and the sampler running on every machine is said.
2026-10-08 16:12:37 +02:00
jochen 0040c008b5 Let the bar render blocks other modules contribute, and give it the battery and power draw from the power module (hq ADR 0255)
The bar left the battery out because it belongs to whoever knows the hardware, and had
no way to take it back in. i3status-rust now renders bar-neutral blocks through its
template; the power module contributes the battery where the machine reports one and
the power draw where something measures it, sampling the root-only energy counter as
root and publishing only a rate. The memory block shows what programs hold, the figure
memory-pressure judges by, instead of counting the cache as used.
2026-10-08 16:12:37 +02:00
jochen 815a55a9fd power: a lock problem is no longer said once the lock is held 2026-10-05 10:03:30 +02:00
jochen 94d0caa09c power: the watcher checks its lock is logind's, and takes it again when it is not
On one server the watcher reported a lock that logind did not list. A descriptor that is not an
inhibitor reference is never wrapped (0 would be the bundle's stdin, its channel to the runtime), and
every poll checks the lock is still held, taking it again and saying why when it is not.
2026-10-04 17:49:19 +02:00
jochen ac1a6fca38 power: the sleep hooks are wanted by the sleep targets, not declared as services
The host reads a one-shot that is not running as having run, so a before-sleep or after-wake unit
declared stopped failed on its first apply; drop-ins on the sleep targets pull them in instead.
2026-10-04 17:22:35 +02:00
jochen 6315556152 power: a machine's power as a module holding node-power; the laptop's resume and lid move onto it (hq ADR 0211)
Code around sleep was written into the service manager's sleep units by the module that needed it,
and the mesh could not tell a sleeping machine from a lost one. power runs every module's code for
the six moments, each piece bounded, owns logind's power handling from its settings, and says
booted, sleeping, woke, shutting-down and the power source on the bus, sleeping under logind's
delay lock before the machine sleeps.
2026-10-04 17:19:27 +02:00
jochen 791d0f62ce WIP: power module (in progress) 2026-10-04 17:14:44 +02:00