mesh/check pass 6724dab0cf96 on 387ee59140c4 | unit 2192 run, 3794 kept, 57 skipped | integration 2208 run, 3829 kept, 57 skipped | over bound: unit, …
On ace's reboot of 2026-10-28 every unit had stopped within 17 s, yet the bus and
polkit were started again during the shutdown, nothing stopped them a second
time, and the reboot waited on reboot.target's 30-minute job timeout, silent,
until the operator forced it. node-power owns the shutdown on every machine, so
its drop-ins on reboot, poweroff and halt shorten the bound; each target keeps
its own forcing action, so the last phase still ends every process, unmounts
and syncs. The cause, node-tools starting bundles again while it stops, is
fixed in mesh-tools.