# brother — the Brother multifunction device: scan, printer state, admin pages One module for one device (novox/hq ADR 0467, issue 1453): the scanner and the printer are one machine on the network, so one module serves both. It claims two seats, each held once for the mesh: `scanner` (verbs `scan`, `status`, `list`) and `printer` (verbs `status`, `settings`; `restart` follows in a later round). It replaces the `scan` module of issue 1440 (ADR 0464), which ran on no node and is gone from the catalogue. ## The scanner seat Built for issue 1440 as novox/hq ADR 0464 decides. It scans the glass of a network scanner (any scanner that speaks eSCL, also called AirScan or Mopria), cuts the document out of the lid's white, files it as a one-page PDF in a folder and says `scan.added` on the bus, so other modules can react. A scan happens when a tool is called: the module runs no process of its own, and it runs as the node's operator account. ## What a scan does 1. Asks the scanner for its glass size and puts one job to it (`POST /ScanJobs`): the platen, the whole glass, at the configured resolution and colour mode, as a JPEG; it fetches the page once. 2. Reads the resolution from the image's own JFIF density, never from the request: a scanner may answer a 300 dpi request with 200 dpi, and the page size and the event's millimetres follow what it gave. 3. Crops: the lid's level is measured in the corner farthest from where documents lie, a pixel is document when it is darker than the lid, and the rows and columns holding enough of them give the box. No document, or one filling nearly the whole glass, keeps the whole image (`cropped` false), and so does `crop` false. 4. Files a one-page PDF holding the JPEG: written whole beside its place as `.scan-*.tmp` and renamed to `scan-YYYY-MM-DD-HHMMSS.pdf` (local time); a taken name gets `-2`, `-3`, and no file is ever overwritten. 5. Says `scan.added` once, after the rename, under the file's sha256 as its message id. It never carries the image. A scanner that refuses or gives no page files nothing and says nothing on the bus; the tool's error says why. ## Config | key | meaning | default | |---|---|---| | `scanner` | the scanner's eSCL address, such as `http://192.0.2.10/eSCL` (required, trusted) | none | | `scan-folder` | the absolute path the PDFs are filed in (required, trusted) | none | | `printer` | the printer's host, such as `192.0.2.10`, for its admin page and IPP (required, trusted) | none | | `printer-certificate` | the SHA-256 fingerprint of the one certificate the admin page may serve, `AA:BB:...` (required, trusted) | none | | `resolution` | dpi asked: 100, 200, 300 or 600 | 300 | | `color-mode` | `color` or `gray` | `color` | | `crop` | cut the document out of the lid's white | true | The values reach the code in one file, `settings.json` in the module's state directory, which the mesh writes from the config; the code reads it at every call. With `scanner` or `scan-folder` unset, every scanner verb says which and writes and asks nothing; `printer` and `printer-certificate` are the printer verbs' to say. The scan folder is not a manifest resource: a directory's path cannot take a config value (issue 1441), so the code makes it (mode 0755) when it files the first scan. ## Tools | verb (tool) | does | |---|---| | `scanner.scan` | scans, crops, files and emits; answers the event's body | | `scanner.status` | whether the scanner answers, its state (Idle or Processing) and its document feeder's state; a scanner that does not answer is `answers: false` with why. This is how its health is read: the module has no long-running resource to declare a health check on | | `scanner.list` | the newest filed scans, newest first (`limit`, default 20). Read-only | ## The printer seat | verb (tool) | does | |---|---| | `printer.status` | without a login: over IPP (`Get-Printer-Attributes`, encoded by hand, on port 631) the state (idle, processing, stopped), the state reasons (such as `toner-low-warning`) and the markers' names, levels (percent; below 0 is unknown) and colours; over eSCL the scanner's state and its feeder's. A part that does not answer is `answers: false` with why. Needs `printer` and `scanner` | | `printer.settings` | logs in, reads one admin page, logs out. Argument `page`: a path on the admin site, starting with `/` and ending in `.html` (default `/general/status.html`). Answers the page's title, links (href and text) and forms with their fields (name, type, value, label); a password field's value is never given. Read-only: it sends the login and the logout and nothing else | ### Trust and the password The admin page is HTTPS with a self-signed certificate. The module verifies no chain: it accepts the one certificate whose SHA-256 fingerprint is `printer-certificate` and refuses any other, in the handshake, so no password is sent to it; the error names both fingerprints. Get the fingerprint from the device's certificate page, and give it as 32 upper-case hex pairs joined by colons. The admin password is the module's own secret `admin-password` (ADR 0467 clause 4; ADR 0283): the operator gives it at their desk, the mesh never generates or rotates it, and it reaches the code as the file `BROTHER_ADMIN_PASSWORD` names (`${dir:state}/admin-password.secret`). While it is not given, `printer.settings` says that the secret is not given and contacts nothing. The login reads the form each time: the device generates the password field's name, so the code takes the name from the form, posts it with the form's hidden fields, and keeps the session cookie. A login is failed when the answer is the login page again. The logout follows a logout link or form on the page; a page with none is said in the answer (`logout`), and the session is left to expire on the device. ## The event `scan.added`, said by this module, on the wire `mesh.mod.brother.event.scan.added`; a consumer declares `brother.scan.added`. Its body: `path`, `node`, `bytes`, `sha256`, `width-mm`, `height-mm`, `resolution` (dpi, as the scanner gave it), `color-mode`, `cropped`, `scanned-at` (RFC 3339, UTC). ## Files it does not know Each directory or archive this module declares says how it treats a file it did not write (ADR 0422, ADR 0416). - `${dir:state}`: everything in it is the program's; the mesh moves nothing out (ADR 0422 §2). - The scan folder (`scan-folder`) is declared by no manifest. The module writes only the `scan-*.pdf` files it files and their `.scan-*.tmp` while they are written; it never changes, moves or removes any other file there, and `scanner.list` only reads. ## Tests The unit tests use the captured answers of a real scanner (`cmd/brother/testdata/escl`, captured 2026-10-20) served by a test HTTP server, the captured IPP exchange (`testdata/ipp`) replayed, and the captured login page (`testdata/admin/login-page.html`) served by a test TLS server with its own certificate. The pages behind the login are synthetic (`testdata/admin/synthetic-*.html`) until round 2 captures the real ones. No test reaches the real device.