jochen 7b5e1d3362 dbus: hold node-message-bus, and never restart the bus live (hq ADR 0215)
A live restart of the system bus during an upgrade hung every login on a
workstation until a reboot. The module owns the bus's packages, declares
the bus running with no restart or reload trigger, publishes only curated
events (health, services, denials; never traffic) and serves tools to look
at both buses.
2026-10-05 11:50:52 +02:00

68 lines
1.9 KiB
Go

package main
import (
"context"
"encoding/json"
"os"
"path/filepath"
"testing"
"time"
)
// Run on a real machine with MESH_LIVE=1: every tool reads this machine's buses, and the watcher's
// connection answers. Nothing is changed.
func TestLiveTools(t *testing.T) {
if os.Getenv("MESH_LIVE") == "" {
t.Skip("set MESH_LIVE=1 on a machine with a system bus")
}
ctx := context.Background()
m := Here()
b, err := DialSystemBus()
if err != nil {
t.Fatal(err)
}
defer b.Close()
if err := b.Ping(ctx); err != nil {
t.Fatal(err)
}
id, _ := b.ID(ctx)
pid, _ := b.PID(ctx, busName)
t.Logf("bus %s, driver pid %d in %s", id, pid, m.UnitOf(pid))
show := func(name string, v any, err error) {
raw, _ := json.Marshal(v)
if len(raw) > 1500 {
raw = append(raw[:1500], "…"...)
}
t.Logf("%s: %v\n%s", name, err, raw)
}
n, err := m.Names(ctx, "system")
show("names system", n, err)
n, err = m.Names(ctx, "session")
show("names session", n, err)
o, err := m.Introspect(ctx, "system", "org.freedesktop.login1", "/org/freedesktop/login1")
show("introspect", o, err)
w, err := m.Monitor(ctx, "system", 2, "", nil)
show("monitor", w, err)
show("health", m.Health(ctx, nil), nil)
show("check", m.Check(ctx, nil), nil)
}
// Run with MESH_LIVE=1: the watcher connects, pings and baselines the names, and says nothing.
func TestLiveWatcher(t *testing.T) {
if os.Getenv("MESH_LIVE") == "" {
t.Skip("set MESH_LIVE=1 on a machine with a system bus")
}
m := Here()
var said []string
w := NewWatcher(m, func(e string, b any) error { said = append(said, e); return nil }, DialSystemBus, m.Denials)
w.state = filepath.Join(t.TempDir(), "bus")
ctx, cancel := context.WithTimeout(context.Background(), PingEvery+2*time.Second)
defer cancel()
w.Run(ctx)
s := w.Snapshot()
t.Logf("%+v said %v", s, said)
if s.BusID == "" || s.LastPingAt == "" || s.Stalled || s.Services == 0 {
t.Fatalf("%+v", s)
}
}