Archived
Found by reading the live mesh's own notes before touching it, which is where this was heading next. Composing the bus's user list was gated on the controller already being on the new bus. That cannot work: the server needs its user list *before* anything moves onto it. Step 2 of the whole change is exactly that — the server stands in the mesh carrying nothing, on its own ports, while every node stays where it is. Under the old gating that step was impossible: the module would come up, find no accounts file, and its entrypoint would wait for one the controller had decided not to write. So the only question is whether this machine runs the module that asked for the file. A mesh that never moves has written a user list nothing reads, costing a few hundred bytes on one node. The reverse cost a step that could not be taken. Pinned by a test over the records of a mesh mid-change: everything running, nothing on the new bus, and a user list that contains the controller — because a file without it is a bus its own writer cannot connect to.