The node-engine held 1,707 top-level unit tests against the budget of 500
a module. Each unit test file with two or more tests now runs them as
subtests of one test named for the file, each named as its function was,
in the same order: every check is kept, and the check counts 383. Files
with a TestMain, a re-run of a test by its name, or the integration tag
are left. Four files of this branch's earlier commits are formatted.
Builds: design 47 H2 §819; H-A-349 DQ-14
The controller ended by its unassignment (issue 1126, ADR 0590), so no build is judged by the lease: the lease
witness, its contract and the direct get the witness asked it with are removed, and its tests now prove each rollback
path on the node tools' PING.
Claude-Session: https://claude.ai/code/session_01NcbgfJ9Gum47zkFKWRaovL
mesh/check pass 65cd7b47873a on bba9081ca127 | carried from 94f9aa298cb8, mesh-sdk 21252194d530 | unit 971 run, 423 kept, 32 skipped | integration 976…
A process no witness judges had its directory removed before the new bundle
was unpacked and the unit restarted, so the old process ran on in a deleted
working directory: mesh-build-go's `go version` probe failed with "getwd: no
such file or directory" and refused three checks on ace on 2026-10-26, each in
the second a new build of it arrived.
Every process is now replaced the way a judged one is: its build is renamed
under .witness/<name>/retired/ and deleted only once nothing runs from it.
"Runs from it" now counts a process's working directory as well as its image,
so the children a daemon starts keep the directory too. Forget keeps a retired
build that still drains, and the witness's sweep covers every process it keeps
a directory for, judged or not.
Two unit-file tests are folded into one, so the unit count goes down by one.
mesh/merge-gate pass: builds mesh-host → ace, g14, novox, shanks; no bus step; every machine composes with the change as it did without (4 of 4 compose)
The witness moved a running controller's build into a 0700 directory and deleted it
on proof, while the old process could still be serving. Its directories are now
0711, and a build without a reader is retired and swept once /proc shows nothing
runs from it.
The launcher trusted a counter only a by-hand reconcile ever cleared and a
known-good nothing in the daemon wrote, so no machine could roll its host back;
the controller and the node tools were replaced in place with nothing kept.
- The launcher runs a delivered host that is not known-good on trial: one that
crashes, stops for nothing, or does not report within ten minutes goes back
to known-good, once per version, recorded in rolled-back. The host proves
itself when the mesh takes a report under its own build, says every standing
verdict on its reports, never stands aside for a rolled-back version, and
restarts its service once when its launcher was replaced on disk.
- The engine keeps the controller's and the node tools' previous build beside
the new one and judges the new one: the lease taken by the controller it
started (read-only direct get of mesh-controller_lease/holder), or this
machine's runtime answering $SRV.PING.node-tools.<node>, within sixty seconds
of time it could ask. Not healthy: the previous restored, once, said. Proved:
the previous deleted. A build declared not-reversible is never rolled back.
- Retire never removes a version newer than the running one.