jschoubben 144362be37 A poll that could not ask has not been answered
`settled` used `must`, so a failed exec ended the wait as though the
machine had reported a failure. It had reported nothing: the control
plane is a container on the node being polled, and while that node
applies a declaration an exec into it can lose its stdout fifo to
containerd. The run then blamed the mesh for a question that missed.

Could not ask and asked, and the answer was bad are different facts, and
only the second is the machine's. A failed poll now keeps the reason and
tries again; the timeout reports whichever came last, so a control plane
that is genuinely unreachable still fails the test — with the reason
rather than with a stack trace.

Every five seconds rather than every two. Each poll is an exec into a
container on a machine that is busy applying, and thirty times a minute
was competing with the apply rather than observing it.
2026-09-01 20:25:54 +02:00
..