node-tools: every wait on the bus in a test waits the shared bound, not a few seconds (issue 1754)
TestAStaleWriteIsRefusedAndWritesNothing gave the watch 5 s to hear a 1 s key's expire and failed main.505's integration step on a loaded build node; TestARunnerAtItsStopAnswersNoCallAndItsCallersMeetNoResponders failed its rerun while it asked 1 s of two round trips and 5 s and 10 s of its waits. The second of a kind after3850eb8, so the kind is fixed: meshtest.Bound (30 s, Until's bound, named once) is what every node-tools test that starts a bus waits for what the bus carries; Until becomes a deadline of it, so a try that waits does not multiply it; an upper bound on how long a call or a wait took is half the bound it tells apart (bus.RequestTimeout, the call's or the wait's own), at most meshtest.Bound. A wait that hears ends then: no passing test is longer (per-test durations before and after, equal). A guard (meshtest waits_test.go) reads every test file that imports meshtest and refuses a wait whose constant bound is a second or more under meshtest.Bound; it names 34 such waits at309069de. Builds: issue 1754 note 8 (the quick fix), note 9 (1754/AC1 to AC4); principle 11
This commit is contained in:
@@ -137,7 +137,7 @@ func TestAConsumerSaysItIsBoundWhileIdleAndOnceWhenTheBusEndedIt(t *testing.T) {
|
||||
for n := 0; n < 3; n++ { // three more intervals pass, counted by the loop's own tick
|
||||
select {
|
||||
case <-ticks:
|
||||
case <-time.After(10 * time.Second):
|
||||
case <-time.After(mt.Bound):
|
||||
t.Fatal("the heartbeat loop handled no more intervals")
|
||||
}
|
||||
}
|
||||
|
||||
Reference in New Issue