TestAStaleWriteIsRefusedAndWritesNothing gave the watch 5 s to hear a 1 s
key's expire and failed main.505's integration step on a loaded build node;
TestARunnerAtItsStopAnswersNoCallAndItsCallersMeetNoResponders failed its
rerun while it asked 1 s of two round trips and 5 s and 10 s of its waits.
The second of a kind after 3850eb8, so the kind is fixed: meshtest.Bound
(30 s, Until's bound, named once) is what every node-tools test that starts
a bus waits for what the bus carries; Until becomes a deadline of it, so a
try that waits does not multiply it; an upper bound on how long a call or a
wait took is half the bound it tells apart (bus.RequestTimeout, the call's
or the wait's own), at most meshtest.Bound. A wait that hears ends then: no
passing test is longer (per-test durations before and after, equal).
A guard (meshtest waits_test.go) reads every test file that imports
meshtest and refuses a wait whose constant bound is a second or more under
meshtest.Bound; it names 34 such waits at 309069de.
Builds: issue 1754 note 8 (the quick fix), note 9 (1754/AC1 to AC4); principle 11
mesh/merge-gate pass: builds mesh-tools, node-tools → ace, g14, novox, shanks; no bus step; every machine composes with the change as it did without (4 of …
An answer larger than the bus's max_payload was refused by the client library
inside its holder, and the caller waited out its 30 s and read silence: the
controller's conditions and status for hours on 2026-10-08. The console now asks
for the parts of an answer the controller paged and joins them; a module's answer
too large for one message is answered as an error saying so, at once.