A worker bound for a pull was kept for the process, so a later connection's pull used a worker bound on a closed connection and answered "connection closed" (every run of TestAHolderPullsOneMessageWhenItHasRoom after the first). The bound workers and the pulled messages are now the Conn's. The two tests that failed main.165 and main.115 asserted on bus figures before the bus had delivered them: the worker's pending count right after a publish, a no-wait pull right after a publish, a callback counter read when a flush returned, a 300 ms delay and a 2 s ack wait a loaded machine overruns. They now count binds on a channel the watcher's reader fills, pull with a wait that ends at the delivery, prove "nothing fetched ahead" by the second message's first delivery, and use bounds a loaded machine stays within. Builds: design 47 H H-A-363 (fix-a-bug-met-twice; whole-module tests under load, H-A-327)
node-tools
The node's tool runtime as a module (novox/hq ADR 0175, to-be 38 WP3). Assigned to a machine, it is one process the host runs from this bundle, as the operator's account: it serves every assigned module's tools and every held seat's verbs on the bus, and answers MCP on the machine's loopback — the console (design 34). The mesh composes the process (which bundles to load, where the credential is, whose machine it is); this manifest says only what the machine must have for it: the interpreter, a place for the credential, the loopback port, and leave to call every tool.
The code is the mesh-tools package in this directory; the module at the repository root,
mesh-tools, builds the images TypeScript bundles are compiled in. See the repository README.