Design 47 H2: H-A-774 (5)-(6), past the bound the stacks first, then the apply in flight; exit 75
This commit is contained in:
@@ -1113,3 +1113,8 @@ mesh-delivery 3b1f03ce, mesh-tools 393449e, mesh-catalog 17e1bfb6 and mesh-sdk b
|
||||
flight (principles 11 and 8). A fact beside it: the packaged unit says TimeoutStopSec=120, but g14's installed unit has
|
||||
no such line (its stop waited the service manager's 90 s on 26 Nov); the installed unit differs from the packaged one,
|
||||
noted on issue 1984, not part of this fix.
|
||||
(5) (20:47, on develop's report) Past the bound, the end first says its line and writes the stacks, then waits for an
|
||||
apply in flight to end and save, as every end of the engine does (issue 1585), and only then exits; the service
|
||||
manager's kill stays the last resort when that wait runs past its own grace. The trace is written in every case, and no
|
||||
apply is cut (principles 3 and 2). (6) The exit status is 75 (EX_TEMPFAIL of sysexits), the one the launcher reads as
|
||||
"start again, not counted".
|
||||
|
||||