Design 47 H2b: H-A-791 to H-A-794, the H2b writer's round-3 questions; the retired word console replaced in H-A-786 and H-A-790

This commit is contained in:
2026-11-26 23:08:01 +01:00
parent 4a22318334
commit 8a37e6694c
@@ -1236,7 +1236,7 @@ mesh-delivery 3b1f03ce, mesh-tools 393449e, mesh-catalog 17e1bfb6 and mesh-sdk b
part of `MESH_TOOL_ENV` and `MESH_TOOL_MODULES`) into a file of that module's own in the runner's bundle directory,
rendered as any composed file; the runner reads them at its start and its watch reloads that one module, make
before break (§844), when its file changes; the unit environment keeps only the runner's own words (its credential
files, the operator account, the console's address). A bundle's move then changes no unit. Principles 2 and 7
files, the operator account, the mesh MCP server's address). A bundle's move then changes no unit. Principles 2 and 7
(the runner's watch is what exists). How it is checked: whole (tool runner): a module's file changed under a
running runner reloads that module alone, and every other module's verb answers throughout; unit (node-engine): a
bundle's move rewrites that module's file and not the runner's unit.
@@ -1271,11 +1271,37 @@ mesh-delivery 3b1f03ce, mesh-tools 393449e, mesh-catalog 17e1bfb6 and mesh-sdk b
- **H-A-790 (`mesh_wait` answers the time it answered, 22:49)** 26 Nov, met twice tonight: two mesh-watchers on the
gate's ledger rebuild stopped early, each saying it has no clock and no tool answered a time; `mesh_wait` answers
only `waited` (read 22:49). The quick fix covers the meantime: the mesh-watcher's definition counts its bound in
waited time (hq #805). The thorough fix, built in H2b (the tool runner's console): every `mesh_wait` answer, heard
waited time (hq #805). The thorough fix, built in H2b (the tool runner's mesh MCP server): every `mesh_wait` answer, heard
or timed out, carries `at`, the time in UTC it answered, so an agent with no shell reads the time from it.
Principles 3 and 4. How it is checked: unit (console): a timed-out wait's answer carries `at` within a second of the
Principles 3 and 4. How it is checked: unit (the mesh MCP server): a timed-out wait's answer carries `at` within a second of the
clock.
- **H-A-787 (answered, 22:53)** The operator chose to move both out of H2b (AskUserQuestion, answered between 22:50:02
and 22:53:22): row 50 (placing the recovery module) goes to the later milestone plan section 8 names, and row 54 (the
gate's note acts) goes to H3, the gate's release. Section 10's milestone column for the two rows says so, and the H2b
file names both in *What needs no line*, with this answer.
- **H-A-791 (no reader-side refusal of a form: the order and `validate` hold it, 23:08)** 26 Nov, the H2b writer's round-3
question 1 (how a reader learns a value's form for §858's refusal). Amends H-A-780: the reader's refusal at decode
is not built. The edge of §858 has the readers run before the writer, and within one pipeline the assigner writes
the writer's want only once the readers report `running` on their machines, its end failing the pipeline (ADR 0682
§8, §9); with H-A-793, a raise no edge covers is refused at `validate`. So no running reader meets a higher form, and
a header or a provision of both forms would be a part without a need. Principle 7; ADR 0682 §8, §9.
- **H-A-792 (the gate's start pass waits on the act's end, built in H2b, 23:08)** Question 2. H-A-690 (2) has the gate
ask `lag` and call `reindex` whole at its start, before `gate_records_follow_ends`'s start pass; that `lag` is the call
that timed out at 21:39 and 21:41 (issue 1984 note 71). §867 changes the runtime's whole-ledger calls into acts, so
the gate, their one caller at a start, changes in the same release: it asks `lag` as an act, calls `reindex` of each
index behind as an act, and begins its start pass on each act's `repair-ended`, said in its journal with the
counts. The gate (`mesh-delivery-gate`, mesh-catalog) joins H2b's row for this line alone; row 54 stays H3's.
design-it-as-it-should-be (every module a change touches in one release), principles 3 and 10.
- **H-A-793 (`validate` refuses a form raise that a reader no edge covers, 23:08)** Question 3. A module that is not
a mover and declares a lower `reads-form` gets no edge, so the raise would reach it unordered: `validate` refuses the
writer's raise and names each such reader with the form it reads; the change raises those readers too, which makes
them movers of the same pipeline. design-it-as-it-should-be (the change carries every module it touches), principle
3. How it is checked: unit (the manifest validator): a raise with an unraised reader is refused, naming it.
- **H-A-794 (the writer's round-3 confirmations, 23:08)** (1) H-A-782 (4) stands; the pin specification's section 8
item 4 heading names the fault ("an empty pin passes"), and the line is its fix: nothing to correct. (2) §866's
tidiness check runs where the toolchain and the registry already are: the Go build module (`mesh-build-go`), at the
start of a Go artifact's unit step, refusing loudly and naming the go.mod and what `go mod tidy` would change; not in
the manifest validator's sandbox. Principle 7. (3) §867's single fold holds its instances in memory: bounded by
`repair-memory-mib` (a setting of the tool runner, default 256); a fold past it ends the act `failed`, naming the
ledger and the bound, and the per-instance call stays the way through. Principles 3 and 11. (4) No other open hq
branch of design 47 holds §856 or higher (read 23:07: #796, #797, #799 and #800 are at lower numbers).