mesh-watcher counts its bound in waited time; H-A-790, mesh_wait answers the time it answered
This commit is contained in:
@@ -27,7 +27,10 @@ the handover names; never report a state you did not read in that round.
|
||||
the work behind it already failed. Each round, also read the journal of the program that does the work
|
||||
(`<node>/node-service-manager.journal` with its unit, the last lines since your previous read) and report any failure
|
||||
line word for word. A verb that times out or refuses twice is a finding of its own: report it at once, never read
|
||||
around it. You have no clock: take times from the tools' answers, never guess them.
|
||||
around it. You have no clock: take times from the tools' answers, never guess them. Your bound and your five minutes are
|
||||
counted in waited time: add up what each `mesh_wait` answer says it `waited`, and the bound of each call that did not
|
||||
answer within it (30 s for a call the runner cut). When the handover gives a bound as a time of day, it also says how
|
||||
many minutes from your start that is; end when your waited time reaches it, never earlier for want of a clock.
|
||||
|
||||
**A report along the way does not end you.** Your final message ends you, and then nothing watches. So while you
|
||||
keep watching, report with `SendMessage` to `main`: when five minutes passed with no change while something
|
||||
|
||||
@@ -1268,3 +1268,10 @@ mesh-delivery 3b1f03ce, mesh-tools 393449e, mesh-catalog 17e1bfb6 and mesh-sdk b
|
||||
it is checked: whole (tool runner): a rebuild of a ledger of 30000 instances answers within a second, says its
|
||||
progress, and its `repair-ended` names the counts; a second rebuild while one runs answers `busy`; unit: a repair
|
||||
without a why is refused.
|
||||
- **H-A-790 (`mesh_wait` answers the time it answered, 22:49)** 26 Nov, met twice tonight: two mesh-watchers on the
|
||||
gate's ledger rebuild stopped early, each saying it has no clock and no tool answered a time; `mesh_wait` answers
|
||||
only `waited` (read 22:49). The quick fix covers the meantime: the mesh-watcher's definition counts its bound in
|
||||
waited time (hq #805). The thorough fix, built in H2b (the tool runner's console): every `mesh_wait` answer, heard
|
||||
or timed out, carries `at`, the time in UTC it answered, so an agent with no shell reads the time from it.
|
||||
Principles 3 and 4. How it is checked: unit (console): a timed-out wait's answer carries `at` within a second of the
|
||||
clock.
|
||||
|
||||
Reference in New Issue
Block a user