Diagnosis — 2026-09-22
- The host publishes a report once per apply and acknowledges the declaration after publishing; that half is sound, and the host logged no failure. The control plane's consumer takes one message at a time and acknowledged every report, recorded or not.
- The store it records into is the foundation store, which the adoption push had just recreated. The control plane's log carried the proof: the report was received and could not be written because the store was starting up.
- Fixed in the control plane. The inventory says whether an error means the store could not be asked right now — a connection that failed, or the server's "connection exception" and "operator intervention" classes, which include starting and shutting down. The recorder marks such a failure as worth another attempt; the consumer waits a moment and hands the report back to the broker, which delivers it again. Any other failure is acknowledged as before, so a report for a node the mesh does not know cannot spin.
How it is checked: a unit test classifies a starting store and a lost connection as "not now" and a constraint the store enforced as an answer; a unit test holds the consumer to handing back a report marked "not now" and acknowledging one refused or recorded. The two-node bed, which found it, runs the adoption push.
Located in: the control plane's report consumer and its recorder. Not a decision.