# Diagnosis — 2026-09-22
|
|
|
|
1. The host publishes a report once per apply and acknowledges the declaration after publishing;
|
|
that half is sound, and the host logged no failure. The control plane's consumer takes one
|
|
message at a time and acknowledged every report, recorded or not.
|
|
2. The store it records into is the foundation store, which the adoption push had just recreated.
|
|
The control plane's log carried the proof: the report was received and could not be written
|
|
because the store was starting up.
|
|
3. Fixed in the control plane. The inventory says whether an error means the store could not be
|
|
asked right now — a connection that failed, or the server's "connection exception" and
|
|
"operator intervention" classes, which include starting and shutting down. The recorder marks
|
|
such a failure as worth another attempt; the consumer waits a moment and hands the report back
|
|
to the broker, which delivers it again. Any other failure is acknowledged as before, so a
|
|
report for a node the mesh does not know cannot spin.
|
|
|
|
**How it is checked:** a unit test classifies a starting store and a lost connection as "not now"
|
|
and a constraint the store enforced as an answer; a unit test holds the consumer to handing back a
|
|
report marked "not now" and acknowledging one refused or recorded. The two-node bed, which found
|
|
it, runs the adoption push.
|
|
|
|
**Located in:** the control plane's report consumer and its recorder. Not a decision.
|