# Diagnosis — 2026-09-22
1. The control plane collects every placed machine's name and address for a resolution keyed by
the internal name (`homer.internal`), because that is the map every container is given as its
hosts. The facts that render the hosts file and the resolver's zones took the same map as bare
names and appended `.internal` to each — their unit tests fed them bare names and passed.
2. Fixed in the facts: a name is read as either form, and each machine is written once as
`<machine>.internal` with its bare name beside it. A test feeds both keyings and holds the files
equal, and holds the zones free of a doubled suffix.
**Located in:** the facts. Not a decision. Proven by the unit test and by the large mesh bed's name
tests, once its controller image is rebuilt from the fix.
*On review.* The first fix wrote the suffix a second time, in the facts, which is the shape that
produced the defect: two places composing one name. The control plane now hands the suffix it
composed the names with down to the facts, so an operator who chose another gets that one and
nothing appended. What remains unproven by a bed is a mesh with a suffix other than the default.