Work slower than the window says so, and one address is the bus's #122

Merged
mesh-admin merged 1 commits from fix/work-longer-than-the-window-says-so into main 2026-09-28 07:51:52 +00:00
Contributor
No description provided.
mesh-admin added 1 commit 2026-09-28 07:51:51 +00:00
Three faults the mesh's own logs showed this morning. A handler that outlives the acknowledgement
window was handed its message again while it was still working: acting on a merge builds modules,
minutes against a thirty-second window, so one merge ran the whole catalogue five times over. The
transport now says the work is in progress while it runs, which is where the window belongs.

Everything the mesh hands out — a token, a membership, a person's credential — took its address
from the enrolment setting, which on a mesh that has moved still names the broker it moved from:
the first person issued after the move was handed the retired broker's port. There is one bus, and
its address is the one the control plane is connected to.

And `operator issue` documented an argument order its parser refused.
mesh-admin merged commit da394b45e6 into main 2026-09-28 07:51:52 +00:00
Sign in to join this conversation.
No Reviewers
No labels
1 Participants
Notifications
Due Date
No due date set.
Dependencies

No dependencies set.

Reference: novox/mesh-controller#122