A module moved to the bus being built was handed a credential for it — nats://
with user, password and fingerprint beside the address — and nothing else in its
environment changed. The runtime always dialled the old bus, so every moved module
kept serving and answered nobody. The scheme in the credential is enough to know
which bus to speak; the nats broker was already written and never chosen.