Only tries a build node holds count toward the 4 at once; tries waiting for a node are bounded
apart at 8, and the refusal names both counts (issue 1890: at 19:53 four tries queued behind 44
checks for up to 47 minutes refused every further try).
The checker wrote a try's asks only at its end, so a 31-minute try could not be told queued from
running (issue 1890). The try's record now names each ask as it is put, then the node that took
it, its state and the phase its step says, written on the step key's own changes. build_usage
names a running try's asks and takes a build module's capacity.<node> (configured bounded by its
node's build CPU, issue 1806's follow-up) when it is current with mesh-config.
A failed test with no cause, or a passing line as its cause, was worded as if it were the failure: a try of mesh-catalog
failed with a passing '✔' line of the first test file. Under mesh-sdk's failure contract the verdict's words and its
status line now start with 'the build module hid the failure (<module> at <version>)', and the check still fails.
The operator's question (how much are the build nodes used, is ace eligible) took six calls over four tools.
build_usage reads it from the bus's states: seats held (have), capacity (mesh-config resolved), pauses, the
build modules' steps by kind with left-running keys, the last hour and day with total and median time and time
at capacity, the running tries, and the backlog the view program reads from the seats' streams. A try now names
the asks it put, and the checker announces its tries readable, so the view tells a try's asks from a check's.
mesh-grants moves to the same mesh-sdk (3203358c), so its shadow user list grants the checker and the builder the
DEAD_LETTERS reads the controller's list will, and the take-over is not blocked by a difference. The checker and the
builder hear DEAD_LETTERS through buildrun.DeadLetterHearing: in the background, again at every reconnect and every ask
waited for while deaf, and keep whether they hear it in their new state hearing, which checker_status and builder_stuck
say as dead_letters. checker_try says that a try ended by the not-taken bound leaves its ask in the stream.
Not done as asked: a module health tool. The catalogue refuses a tool check on a module with no runtime of its own and no
other check beside it (ADR 0227 rule 8, ADR 0366 §1), so the deaf state is said in the status tools and the log.
The waiter moved to mesh-sdk buildrun (fix/734-lost-ask, d96b9fd6), where every asker of the build seats shares it.
The builder hears DEAD_LETTERS for the go, node and image seats and asks a given-up part of a build again at once, with
the seat's words as why, instead of waiting for the check bound. The checker keeps what it does with a lost ask (a try
ends as error, a check is asked again) and its verdict words.
A check ask handed out five times during a bus reload was given up into DEAD_LETTERS and no build node wrote a step for it,
so try-1793017340003993788 stayed running for ever, held one of the four try places, and checker_try of its head kept
answering its id. The checker now hears the copies DEAD_LETTERS keeps of the build seats' given-up asks (an ordered
consumer from its start; the grant is mesh-sdk/mesh-controller DeadLetterReads, branch fix/734-lost-ask) and ends the
step it waits for: a try ends as error saying why, a check is asked again under its claim, up to three times, then fails
as not heard. A try whose ask no node takes within the step bound ends the same way (a check's backlog stays no fault,
ADR 0525 §9). checker_try_end ends a try by hand, freeing its place and stopping its judging.
A check that landed on ace passed with mesh-build-node's integration tests skipped. The build module now leaves such a
package unmet; the checker keeps the passes and asks the levels from the first unmet one with the need named, putting the
ask again under a new id when a node lacking it declines it. Re-pins mesh-sdk feat/890-placement.
mesh/check failed: ace: the check of novox/mesh-catalog#492 refused: the installed go version could not be read: `go version` with GOTOOLCHAIN=local f…
mesh/check failed: ace: the check of novox/mesh-delivery#65 refused: the installed go version could not be read: `go version` with GOTOOLCHAIN=local f…
The checker stopped reading a level's test results at the first that did
not pass and kept only its first failure, so a check named one fault per
round. It now reads and counts every result and writes every failed test
with its first line into the verdict's Failures and the try's failed
list (at most 50, then how many more); Failed keeps the first one's
words whole (issue 1901). Pins mesh-sdk fix/1921-every-failure.
builder_stuck, checker_kept, checker_verdicts, checker_status, checker_previews, checker_pull and checker_try listed a
bucket of thousands of keys and read each value (builder_stuck also its history) one round trip at a time before
filtering, so they timed out at 30 s. Now keys are narrowed by what the key carries first, history is read only for rows
kept, values are read sixteen at a time, at most 1000 a call with the answer saying it was cut, steps newest first, a new
try reads only the newest 64 tries, and each tool logs the values read and the time taken. Same kind as the view's fix
(PR 52); the helper is copied, not put in mesh-sdk, as a few lines do not earn a group delivery.
mesh/delivery-group group fix/1901-package-cause held: a member is held: novox/mesh-catalog@155124b59af4 (merged without a passing check: only a person decides…
mesh/check pass dd9138310c48 on 51444a834173 | unit 2015 run, 2883 kept, 5 skipped | integration 2037 run, 2978 kept, 9 skipped | over bound: unit, in…
The build module on main sends a timeout, exit or kill as only 'FAIL <pkg>':
dropping summary lines left empty words. They now say the package failed with
no cause sent. Causes match at column 0 only, summary lines only in go's exact
forms, and the words count the cause, the marker and the newlines within
MaxWords.
An older build module's output for a race after the tests' PASS is now worded
by the race's heading, access and frame, not by go test's PASS or the report's
separator line (1901/AC5).
A try of mesh-controller's status read 'cmd/mesh-controller: PASS': the build
module sent a package failure whose output began with go test's PASS. The
checker now drops go test's summary lines, takes the first panic, fatal error
or signal line as the cause when the build module told none apart (read before
the words are cut), says the tests passed and the program failed after them
when nothing else is left, and cuts a cause to 1 KB so the words keep their
bound (1901/AC5).
mesh/delivery covered after its failure: a later walk that contains it was delivered: plan-1792794985391468127 (novox/mesh-delivery at 45ab9947 into main…
mesh/delivery covered after its failure: a later walk that contains it was delivered: plan-1792777718506798022 (novox/mesh-delivery at fae4d48e into main…